Urban trees in numerical simulations: Tree modelling and resolution requirements for thermal load assessment
Queck, Ronald; Bienert, Anne; Richter, Katja; Blaskow, Robert; Graumann, Elena
Meteorologische Zeitschrift (2026)
published online: Sep 15, 2026
manuscript accepted: May 16, 2026
final revised version received: Oct 9, 2025
manuscript revision requested: Aug 2, 2025
manuscript received: May 10, 2025
DOI: 10.1127/metz/1283
Open Access (paper may be downloaded free of charge)
Abstract
Urban trees play a crucial role in shaping the local microclimate by reducing thermal loads, a phenomenon that can be quantified through numerical simulations. However, achieving accurate simulation results requires detailed vegetation models as input data. As the computational cost of simulations increases exponentially with the complexity of vegetation models, it is not feasible to use arbitrarily high resolutions. This study investigates the spatial resolution required in numerical simulations to adequately capture the effects of trees on the thermal stress in streets in an urban study area with mid-rise buildings. A workflow was developed to efficiently generate vegetation models with the necessary resolution using optical measurement methods. By investigating the outdoor thermal comfort experienced by urban inhabitants at levels below tree crowns, the study focuses on grid spacing in simulations that resolve vegetation canopies. Various data sources were used to create digital vegetation models with different resolutions: municipal tree cadastre data (MTC), airborne laser scanning (ALS) and terrestrial laser scanning (TLS). Exemplarily for other urban climate models, the large-eddy simulation (LES) model PALM-4U was employed to determine the optimal grid spacing for simulating the effects of vegetation. The grid size ranged from 0.5 m to 10 m. The level of detail (LoD) of all other urban topographical elements was kept constant at in order to avoid mixing the effects of the grid spacing of buildings and trees. The results of PALM-4U were validated against meteorological measurements collected via a mobile platform with element-scale resolution (i. e. ~ 1 m). The findings indicate that tall vegetation has a significant cooling effect. On a hot summer day, comparisons between densely and sparsely vegetated street sections revealed local differences in physiological equivalent temperature (PET) of up to 15 K, as observed in the measurements. Simulations using a grid spacing of 1 metre or less agreed very well with the measured values. In contrast, the coarsest grid spacing of 4 m resulted in a reduced local temperature difference of only 5 K between densely and sparsely vegetated street sections. These results suggest that a grid spacing of 1 m is required for reliable simulation of microclimatic effects of urban trees. Coarser grid spacings significantly underestimate small-scale effects, with errors increasing as grid size increases. Although these findings are limited to the LES PALM-4U, they offer valuable insights into the efficient integration of vegetation into urban climate models, balancing computational effort with simulation accuracy. Furthermore, small-scale differences in shading, ventilation, and thermal stress emphasise the effectiveness of mitigation efforts in specific urban hotspots, which can serve as a basis for city-wide strategies.
Keywords
urban trees • plant area density • terrestrial laser scanning • airborne laser scanning • urban climate simulation • PALM-4U